LIST
NOMENCLATURE
of marketable products through put Kant Cement & Roof tales Factory.
CEMENT
Cement
type |
Standard
name |
Lg-loss |
Chemical
composition, % |
Physical
data |
||||||||
|
Sio2 |
A|203 |
Fe20 |
CaO |
MgO |
SO3 |
Total
|
Bending |
Compressive |
Specific |
||
Portlandcement with mineral additives |
10178-85 (bc
12:1989) |
2,69 |
22,99 |
4,63 |
3,97 |
60,14 |
2,19 |
2,10 |
98,71 |
6,0 |
42,5 |
300 |
Directions for use: for reinforced and mass
concrete constructions, for production of precast concrete with uses steamed
concrete type to 200; for concrete of way and airship cover, in the uses not
more 15% of the part a slag. |
||||||||||||
Plastic Portlandcement |
10178-85 |
2,69 |
22,99 |
46,66 |
4,04 |
59,93 |
2,19 |
2,26 |
98,59 |
6,5 |
4,8 |
322 |
Directions for use: for external uses part of
hidrotechnic constructions, of way and airstrip cover, and also other
constructions, subject to coagulation and thawing out many team. |
||||||||||||
Sulfate resistant portlandcement |
10178 |
1,83 |
23,30 |
4,73 |
4,80 |
59,92 |
2,23 |
2,15 |
98,95 |
6,0 |
43,7 |
285 |
Directions for use: for concrete and
reinforced concrete constructions, subject a sulfate aggressions on the level
a variable of water. |
||||||||||||
Portlandcement without additives |
|
|
20,70 |
|
|
|
|
|
|
|
|
|
Directions for use: for concrete of way and airstrip
cover, reinforced concrete pipes for high and low pressure, reinforced
concrete railway sleeper, bridge constructions, voltaic pile for contact net
of railroad and light, article asbestoscement. |
||||||||||||
М-400 W/A |
10178-85 |
1,45 |
22,77 |
4,94 |
4,80 |
60,03 |
2,26 |
2,75 |
98,40 |
6,3 |
44,8 |
280 |
Directions for use: for hidrotechnic
constructions and prestressed reinforced concrete constructions, subject a sulfate
aggressions and also for bearing pile, bridge constructions, intend for
utilization in mineral water. |
SLATE
Slate
type |
Standard
name |
Length,
mm |
Technical
data |
||
Breadth,
mm |
Bending
strength, kgs/cm2 |
Wave
height of cover, mm |
|||
UV – 6,0 (6 wave) SV – 40 (8 wave) |
GOST
20430-84 GOST
20450-84 |
1750
+/- 15 1750
+/-15 |
1125
+10/-5 1130
+10/-5 |
16,0 16,0 |
45
+4/-6 30
+6/-4 |
Directions for use: as covering of roof |
PIPES
Product
name |
Standard
name GOST |
Technical
data |
||||
External
diameter, mm |
Internal
diameter, mm |
Length,
mm |
Crushing
strength, kgs |
Collapsing
pressure, kgs/cm2 |
||
Asbestos
cement pipes: VT – 9, pressure, diameter of: 150
мм 200
мм 300
мм 400
мм |
11310-90 11310-90 11310-90 11310-90 |
168 224 324 427 |
141 189 279 368 |
3950 3950 3950 3950 |
1210 1320 1540 1980 |
31 31 27 27 |
Directions for use: for hydraulic pipes. |
||||||
Drain
pipes: BN 150 мм BN 200 мм BN 300 мм BN 400 мм |
11310-90 11310-90 11310-90 11310-90 |
161 +/-2,5 211 +/-2,5 307+/-3,0 402 +/-3,0 |
141 189 279 368 |
3950 3950 3950 500 |
400 320 420 |
|
Directions
for use: for drain and irrigation canalizations and telephone communication
etc. |
ADAPTING PIPES
Product
name |
Standard
name GOST |
Technical
data |
|||
External
diameter, mm |
Internal
diameter, mm |
Length,
mm |
Collapsing
pressure, kgs/cm2 |
||
Asbestos cement adapting pipes: SAM – 9, pressure, diameter of: 150
мм 200
мм 300
мм 400
мм |
11310-90 11310-90 11310-90 11310-90 |
225,5 287,0 397,0 517,0 |
173,5 229,5 329,5 433,5 |
140 150 150 160 |
18 18 18 18 |
For drain pipes: BN 150 мм BN 200 мм BN 300 мм BN 400 мм |
11310-90 11310-90 11310-90 11310-90 |
212,0 260,0 366,0 477,0 |
188 +/-2,0 234 +/-2,0 344 +/-3,0 441 +/-3,0 |
150 +/-3,0 150 +/-3,0 150 +/-3,0 150 +/-3,0 |
4 4 4 4 |
Directions for use: as connective elements
for asb/cem.pipes. |